Complete CHeKT Product Catalog
CKB308
Datasheet

CKB-308

The CKB-308 8-Channel Visual Security Bridge is POE powered video security panel for security professionals to connect cameras, alarm sensors and video analytics for cloud-based visual security and video alarm monitoring.

  • 8 Camera Channels
  • Event Triggers; Camera Analytics, Physical Sensors, & API Events
  • Pair Cameras with Existing Alarm Panel Zones
  • 1 Normally Open and Closed Controllable Relay Output
  • Arming & Disarming Options
  • Converts Video Analytics Alarm Signals for Central Station Response
  • IP Audio Integration for Audio Messaging
  • Line-level Analog Audio Capability
  • End-User Mobile App
  • POE Power or 12v DC
TECHNICAL

Product Specifications

General
Model CKB308
Digital Alarm Inputs 8 Physical Input Zones
Relay Output 1 x Relay Output (NO/NC) – 100mAmps @24v DC
Audio Output 1/8″ (3.5mm) Line Level Output (non-amplified)

IP Audio Integrations

Reset Button Bridge Factory Reset
LED Indicators
STA (Status) Bridge Power – On (Armed Status – Red[Armed] ; Green[Disarmed])
Net (Network) Network Connection Indicator
DI (Alarm 1-4) Physical Input Indicators (Red – Alarm, Off – Normal)
Operational
Video Source Recommendations IP devices with available RTSP Stream. Video Source Requirements:~ D1 Resolution: 720×480 & 6 FPS
Video Compression Support H.264
Video Authentication Options ONVIF, RTSP, HTTP
Video Transmission Security TLS/SSL Encryption to Cloud and Central Station
Video Analytics Support ONVIF Event Messaging Protocol, API Calls
Event Triggers Physical Input Zones, ONVIF Event Topics, AI via Local API
Alarm Events Alarm Communication via IP to Central Station Automation
Audio In Available on supported cameras with audio in the video stream
Network
Ethernet RJ-4510/100/BASE-T Connection
EncryptionSecurity TLS/SSL (Secure Socket Layer)
Environmental & Electrical
Operating Temperature /Humidity 0C ~ +40°C (32°F ~ 85°F) / Less than 85% RH
Bridge Power Source POE & 12v DC
Power Consumption 800mAmps Peak
Physical Input Zones Input Voltage Range: 0-12v DC (All Ground Termals Are Common)
Relay Output max 100mApms @24v DC
Arming Input Input Voltage Range: 0-12v DC (All Ground Termals Are Common) – 1.87v ADC Reading with no external Connection

Scheduled Arming

Mobile App Arming

API Arming

Mechanical
Color / Material White / Polycarbonate (PC)
Product dimensions / weight 82mm x 100.7mm x 36mm (3.2″ x 3.9″ x 1.4″), Weight : 170g (0.4lb)
BUY NOW
CHeKT Trusted Distribution Partners
SS&SI CHeKT Equipment
ADI CHeKT Equipment
Anixter 2024
SES 2024
Ameta 2024
arrowhead